ALTALINK - Customer mode / Finition / NVM
Pour entrer en mode tech :
procedure NVM ALTALINK mode tech.docx
Nom CUSTOMER Mode
- Power on the machine, and enter UI diagnostics (CSE mode).
- Go to NVM location 616-014 (system install phase) and change the value to "2".
- Exit diagnostics and reboot the machine.
- Follow the Install Wizard to correctly set the date and time, etc.
- If the machine hangs and won't complete the wizard, go to NVM location 616-014, and change the value to "4".
- Exit diagnostics and reboot the machine.
- Enter Tools, and set Date and Time, Language, Measurement (inch or metric), and Paper Size Preference (inch or metric).
Module FINITION non reconnu
Menu Adjustements
Choix = DC131 NVM R/W
entrer la valeur 742-869, puis read
mettre à 0 (elle etait à 1), confirm, write
exit, log + reboot